Calculated-industries 4095-C User Guide Manual de usuario Pagina 39

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 65
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
40 — PiPe Trades Pro
Combination Rolling Offset
Unlike a regular rolling offset, the entry and exit ttings for a
combination rolling offset are on different planes and therefore
have different tting angles from each other.
Horizontal to Vertical
Find the pipe length, and entry and exit tting angles for a
combination rolling offset with a vertical pipe exit, given a
Roll of 23”, Offset of 15”, and Advance of 29. Use the box in
Diagram 1 to review the entry and exit pipe perspectives.
0’ -29”
ADVANCE
0’ - 15”
Offset
0’ - 23”
Roll
Unknown
Entry Fitting
Angle
Diagram 1
KEYSTROKE DISPLAY
ALL CLEArEd
1. Solve for the pipe length and entry tting angle
OFST 15 INCH
(Advance) RUN 29 INCH
(Roll) LNTH 39-15/16 INCH
FIT° 43.4
Do not clear or reset the calculator.
If the box is oriented in a 2-dimensional perspective (Diagram 2),
Vista de pagina 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 64 65

Comentarios a estos manuales

Sin comentarios