Pagina 1 - Digital AreaTake-Off Tool

USER’SGUIDEDigital AreaTake-Off ToolModel#6250

Pagina 2 - INTRODUCTION

USER’S GUIDE — 7FINAL ASSEMBLYThe ultrasonic beams are sent from the right arm of the Puck to the top bar, then refl ected back, and from the left arm

Pagina 3

GETTING STARTEDOnce assembly and setup are complete, proceed with the following steps in order to begin measuring.1. When placing the bars and securin

Pagina 4 - TABLE OF CONTENTS

Right-Hand Confi guration ShownUSER’S GUIDE — 9

Pagina 5 - PACKAGE CONTENTS

10 — ULTRA SCALE MASTER®[END] Ends polyline measurement, displaying the total perimeter.[CLOSE —]Completes the polygon and displays the calculated are

Pagina 6 - USER’S GUIDE — 3

USER’S GUIDE — 11[ON/CLEAR]Turns the unit ON and clearsthe display. Holding down the[ON/CLEAR] key for 1.5 seconds also powers the unit off.[CLOSE +]C

Pagina 7 - RIGHT-HAND ASSEMBLY

[UNDO]Undoes the previous measurement. Allows you to undo the last ten measurements (if applicable) while in measure mode. If a measurement has been c

Pagina 8

[M+]Adds the displayed value to accumulative memory (except when setting a Custom Scale).[SET] [M+] (M—)Subtracts the displayed value from the accumu

Pagina 9 - LEFT-HAND ASSEMBLY

[MODE]Used to select from the list of available modes (see Built-In Scales section).[SET] [MODE]Used to move back through the list of available modes.

Pagina 10 - FINAL ASSEMBLY

[UNITS]Used to select from the list of available units of measurement (see Units of Measurement section).[SET] [UNITS]Used to move back through the li

Pagina 11 - GETTING STARTED

The Top Legend displays the following:• SET• M (Memory)The Measure Status and number of sides are displayed here (End or Closed are displayed only whe

Pagina 12 - USER’S GUIDE — 9

INTRODUCTION The Ultra Scale Master has been specifi cally designed to simplify take-offs for all fi elds of construction. Use it for estimating proje

Pagina 13 - KEY DEFINITIONS

BUILT-IN SCALESThe following modes and scales are available for selection using the [MODE] and [SCALE] keys, depending on whether the puck is set to I

Pagina 14 - USER’S GUIDE — 11

• Only one shape can be measured at a time • A measured Area cannot contain lines that cross each otherSHAPES AND DEFINITIONSThe Ultra Scale Master ca

Pagina 15 - FUNCTION KEYS

12MEASURING POLYLINESOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and press the

Pagina 16 - USER’S GUIDE — 13

MEASURING SIMPLE POLYGONSOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and press

Pagina 17 - SETUP KEYS

MEASURING TAKE-OUTSOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and press the [

Pagina 18 - USER’S GUIDE — 15

AREAADJUSTED AREA5. Press the [CLOSE+] key. The total Area is displayed.6. Press the [M+] key to store the Area in Memory, then repeat steps 1 through

Pagina 19 - USING THE ULTRA SCALE MASTER

USER’S GUIDE — 23MEASURING COMPLEX POLYGONSOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi r

Pagina 20 - Modes Scales

MEASURING IRREGULAR SHAPESOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and pres

Pagina 21 - POLYLINE:

There are two methods for programming Custom Scales into your Ultra Scale Master. “Measured Custom Scales” allow you to measure a specifi ed Length and

Pagina 22 - ILLEGAL SHAPE:

5. The displayed units begin fl ashing, indicating that they are ready to be changed. Press [UNITS] to scroll through the available units.*6. Use [MR]4

Pagina 24 - MEASURING TAKE-OUTS

SETTING AN ENTERED CUSTOM SCALE (IMPERIAL MODE)1. Press [MODE] until “CUST” is displayed.2. Press [SET] then press [SCALE] [SCALE] to begin entering t

Pagina 25 - 22 — ULTRA SCALE MASTER

28 — ULTRA SCALE MASTER®LINEAR UNITSFeet-Inch (FEET INCH)*Feet (FEET)Yards (YD)Meters (M)**Centimeters (CM)Millimeters (MM)Inch (INCH)AREA UNITSSquare

Pagina 26 - MEASURING COMPLEX POLYGONS

USER’S GUIDE — 29APPENDIX A APPENDIX BACCURACY/ERRORS/AUTO SHUT-OFFAccuracy/Display Capacity – The Ultra Scale Masterhas a seven-digit main display,

Pagina 27 - MEASURING IRREGULAR SHAPES

30 — ULTRA SCALE MASTER®APPENDIX C APPENDIX DSPECIFICATIONS REPAIR AND RETURNWARRANTY, REPAIR AND RETURN INFORMATIONReturn Guidelines1. Please read t

Pagina 28 - CUSTOM SCALES

USER’S GUIDE — 31If a defect exists during the warranty period, CI, at its option, will either repair (using new or remanufactured parts) or replace (

Pagina 29 - 26 — ULTRA SCALE MASTER

Software copyrighted and licensed toCalculated Industries, Inc. byScale Master Technologies, LLC, 2007.User’s Guide copyrighted byCalculated Industrie

Pagina 30 - USER’S GUIDE — 27

TABLE OF CONTENTS SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2PACKAGE CONTENTS . . . . . . .

Pagina 31 - UNITS OF MEASUREMENT

2 — ULTRA SCALE MASTER®Ultra Scale Master Pro model 6250 (Puck)SETUPPACKAGE CONTENTSYour package contains the following pieces:Female End CapCorner Co

Pagina 32 - APPENDIX A APPENDIX B

USER’S GUIDE — 3Male End CapShort Refl ector BarLong Refl ector BarCarrying CaseUser’s Guide,Quick Reference Guide,and Quick Setup Sheet

Pagina 33 - APPENDIX C APPENDIX D

RIGHT-HAND ASSEMBLYAssemble the refl ector bars as shown. Align the corner connector at a 90° angle at the top left corner of the plans.5. Slide Female

Pagina 34 - USER’S GUIDE — 31

4. Insert the Male End Cap into the female end of the Short Refl ector Bar. The Male End Cap is preinstalled for a Right-Hand confi guration.3. Insert t

Pagina 35

6 — ULTRA SCALE MASTER®NOTE: Sloping side of the Refl ector Bars face outward.5. Insert the the male end of the second Long Refl ector Bar into the fema